Call us+351 912 324 600Email Usinfo@airconalgarve.com

Mitsubishi Air Conditioning Heat Pump Inverter Floor Mounted

ManufacturerMitsubishi

Mitsubishi Electric Air Conditioning Heat Pump Inverter MFZ-KA25VA Floor Mounted (2.5 kW / 9000Btu) 240V~50hZ
Sales price £1,226.55

Preloader

This series is extremely versatile and is designed for wall attached installation at floor level.  The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation Easy. High C.O.P of 4.07. 

Product Key Features

• Super High CoP 4.07
• Advanced technology control
• Infra-red controller with wall mounting bracket                                              
• Super compact construction mm - 700 x 200 x 600
• Pipe runs up to 20 metres
• Low noise – 22dBA on low
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 7 metres pipe length

MFZ-KA25VA Indoor Unit

Capacity (kW):
Heating (Nominal) (Low - High) 3.40 (0.90 - 5.10)
Cooling (Nominal) (Low - High) 2.50 (0.90 - 3.40)
Heating (UK) (Low - High) 2.85 (0.75 - 4.25)
Cooling (UK) (Low - High) 2.50 (0.90 - 3.35)
SHF R410A (Nominal) 0.66
COP / EER (Nominal) 4.07 / 4.31
Energy Label Heating / Cooling A / A
Width - mm 700
Depth - mm 200
Height - mm 600
Weight - kg 14
Airflow (m3/min) (Heating / Cooling) - Lo-Mi-Hi-SupHi 5-6.2-7.6-9.1 / 4.8-5.8-7.1-8.7
Noise (dBA) (Heating / Cooling) - Lo-Mi-Hi-SupHi 22-27-32-37 / 22-27-32-37
Pipe Size Gas mm (in) 9.52 (3/8)
Pipe Size Liquid mm (in) 6.35 (1/4)
Electrical Supply Fed by Outdoor Unit
Phase Single
Fuse Rating (BS88) - HRC (A) 6
Interconnecting Cable No. Cores 4

SUZ-KA25VA Outdoor Unit

Width - mm 800
Depth - mm 285
Height - mm 550
Weight - kg 33
Noise (dBA) (Heating / Cooling) 46 / 46
Electrical Supply 220-240v, 50Hz
Phase Single
Fuse Rating (BS88) - HRC (A) 10
System Power Input (kW) - Heating (Nominal) 0.835
System Power Input (kW) - Cooling (Nominal) 0.58
System Power Input (kW) - Heating (UK) 0.76
System Power Input (kW) - Cooling (UK) 0.46
Starting Current (A) 3.8
System Running Current (A) - Heating / Cooling 4 / 2.8
Mains Cable No. Cores 3
Max Pipe Length (m) 20
Max Height Difference (m) 12
Charge (kg) - 7m 0.9